To determine whether collateral ventilation (defined as the ventilation of alveolar structures through passages or channels that bypass the normal airways) changes with age or emphysema, we compared the mechanics of collateral ventilation in seven young normal subjects, three old normal subjects and five patients with emphysema. In supine normal subjects at the end of a quiet expiration, resistance to airflow was greater through collateral channels than through bronchi and bronchioles. In emphysema, airways resistance could exceed collateral resistance, causing air to flow preferentially through collateral pathways. We conclude that high collateral resistance minimizes collateral airflow in supine normal subjects. When peripheral airways become obstructed or obliterated in emphysema, collateral channels may provide for more even distribution of ventilation.
This article has been cited by other articles:
Fessler, H. E., Scharf, S. M., Ingenito, E. P., McKenna, R. J. Jr., Sharafkhaneh, A.
(2008). Physiologic Basis for Improved Pulmonary Function after Lung Volume Reduction. Proc Am Thorac Soc
5: 416-420
[Abstract][Full Text]
Bartel, S.-E. T., Haywood, S. E., Woods, J. C., Chang, Y. V., Menard, C., Yablonskiy, D. A., Gierada, D. S., Conradi, M. S.
(2008). Role of collateral paths in long-range diffusion in lungs. J. Appl. Physiol.
104: 1495-1503
[Abstract][Full Text]
Cardoso, P. F.G., Snell, G. I., Hopkins, P., Sybrecht, G. W., Stamatis, G., Ng, A. W., Eng, P.
(2007). Clinical application of airway bypass with paclitaxel-eluting stents: Early results.. J. Thorac. Cardiovasc. Surg.
134: 974-981
[Abstract][Full Text]
Verbanck, S., Paiva, M.
(2007). Simulation of the apparent diffusion of helium-3 in the human acinus. J. Appl. Physiol.
103: 249-254
[Abstract][Full Text]
Choong, C. K, Macklem, P. T, Pierce, J. A, Lefrak, S. S, Woods, J. C, Conradi, M. S, Yablonskiy, D. A, Hogg, J. C, Chino, K., Cooper, J. D
(2007). Transpleural ventilation of explanted human lungs. Thorax
62: 623-630
[Abstract][Full Text]
Polkey, M. I., Hopkinson, N. S.
(2006). Bronchoscopic lung volume reduction. ERR
15: 99-103
[Abstract][Full Text]
de Oliveira, H. G., Macedo-Neto, A. V., John, A. B., Jungblut, S., Prolla, J. C., Menna-Barreto, S. S., Fortis, E. A. F.
(2006). Transbronchoscopic Pulmonary Emphysema Treatment: 1-Month to 24-Month Endoscopic Follow-up.. Chest
130: 190-199
[Abstract][Full Text]
Cetti, E J, Moore, A J, Geddes, D M
(2006). Collateral ventilation. Thorax
61: 371-373
[Full Text]
Higuchi, T, Reed, A, Oto, T, Holsworth, L, Ellis, S, Bailey, M J, Williams, T J, Snell, G I
(2006). Relation of interlobar collaterals to radiological heterogeneity in severe emphysema. Thorax
61: 409-413
[Abstract][Full Text]
O'Donnell, D E, Parker, C M
(2006). COPD exacerbations {middle dot} 3: Pathophysiology.. Thorax
61: 354-361
[Abstract][Full Text]
Venuta, F., Rendina, E. A., De Giacomo, T., Anile, M., Diso, D., Andreetti, C., Pugliese, F., Coloni, G. F.
(2006). Bronchoscopic procedures for emphysema treatment. Eur. J. Cardiothorac. Surg.
29: 281-287
[Abstract][Full Text]
Choong, C. K., Phan, L., Massetti, P., Haddad, F. J., Martinez, C., Roschak, E., Cooper, J. D.
(2006). Prolongation of patency of airway bypass stents with use of drug-eluting stents. J. Thorac. Cardiovasc. Surg.
131: 60-64
[Abstract][Full Text]
Woods, J. C., Yablonskiy, D. A., Choong, C. K., Chino, K., Pierce, J. A., Hogg, J. C., Bentley, J., Cooper, J. D., Conradi, M. S., Macklem, P. T.
(2005). Long-range diffusion of hyperpolarized 3He in explanted normal and emphysematous human lungs via magnetization tagging. J. Appl. Physiol.
99: 1992-1997
[Abstract][Full Text]
Choong, C. K., Haddad, F. J., Gee, E. Y., Cooper, J. D.
(2005). Feasibility and safety of airway bypass stent placement and influence of topical mitomycin C on stent patency. J. Thorac. Cardiovasc. Surg.
129: 632-638
[Abstract][Full Text]
Fessler, H. E.
(2005). Collateral Ventilation, the Bane of Bronchoscopic Volume Reduction. Am. J. Respir. Crit. Care Med.
171: 423-424
[Full Text]
Rendina, E. A., De Giacomo, T., Venuta, F., Coloni, G. F., Meyers, B. F., Patterson, G. A., Cooper, J. D.
(2003). Feasibility and safety of the airway bypass procedure for patients with emphysema. J. Thorac. Cardiovasc. Surg.
125: 1294-1299
[Abstract][Full Text]
Lausberg, H. F., Chino, K., Patterson, G. A., Meyers, B. F., Toeniskoetter, P. D., Cooper, J. D.
(2003). Bronchial fenestration improves expiratory flow in emphysematous human lungs. Ann. Thorac. Surg.
75: 393-398
[Abstract][Full Text]
Denehy, L., Berney, S.
(2001). The use of positive pressure devices by physiotherapists. Eur Respir J
17: 821-829
[Abstract][Full Text]
KAMINSKY, D. A., BATES, J. H. T., IRVIN, C. G.
(2000). Effects of Cool, Dry Air Stimulation on Peripheral Lung Mechanics in Asthma. Am. J. Respir. Crit. Care Med.
162: 179-186
[Abstract][Full Text]