We identified characteristics of devices that caused needle-stick injuries in a university hospital over a 10-month period. Hospital employees who reported needle sticks were interviewed about the types of devices causing injury and the circumstances of the injuries. Of 326 injuries studied, disposable syringes accounted for 35 percent, intravenous tubing and needle assemblies for 26 percent, prefilled cartridge syringes for 12 percent, winged steel-needle intravenous sets for 7 percent, phlebotomy needles for 5 percent, intravenous catheter stylets for 2 percent, and other devices for 13 percent. When the data were corrected for the number of each type of device purchased, disposable syringes had the lowest rate of needle sticks (6.9 per 100,000 syringes purchased). Devices that required disassembly had rates of injury of up to 5.3 times the rate for disposable syringes. One third of the injuries were related to recapping. Competing hazards were often cited as reasons for recapping. They included the risk of disassembling a device with an uncapped, contaminated needle and the difficulty of safely carrying several uncapped items to a disposal box in a single trip. New designs could provide safer methods for covering contaminated needles. Devices should be designed so that the worker's hands remain behind the needle as it is covered, the needle should be covered before disassembly of the device, and the needle should remain covered after disposal. Such improvements could reduce the incentives for recapping needles and lower the risk of needle-stick injuries among health care workers.
Source Information
Department of Neurosurgery, University of Virginia, Charlottesville 22908.
This article has been cited by other articles:
Peng Bi, , Tully, P. J., Boss, K., Hiller, J. E.
(2008). Sharps Injury and Body Fluid Exposure Among Health Care Workers in an Australian Tertiary Hospital. Asia Pac J Public Health
20: 139-147
[Abstract]
Elder, A., Paterson, C.
(2006). Sharps injuries in UK health care: a review of injury rates, viral transmission and potential efficacy of safety devices. Occup Med (Lond)
56: 566-574
[Abstract][Full Text]
Fitzner, J., Aguilera, J.-F., Yameogo, A., Duclos, P., Hutin, Y. J. F.
(2004). Injection practices in Burkina Faso in 2000. Int J Qual Health Care
16: 303-308
[Abstract][Full Text]
Varghese, G M, Abraham, O C, Mathai, D
(2003). Post-exposure prophylaxis for blood borne viral infections in healthcare workers. Postgrad. Med. J.
79: 324-328
[Abstract][Full Text]
Sulkowski, M. S., Ray, S. C., Thomas, D. L.
(2002). Needlestick Transmission of Hepatitis C. JAMA
287: 2406-2413
[Abstract][Full Text]
Sagoe-Moses, C., Pearson, R. D., Perry, J., Jagger, J.
(2001). Risks to Health Care Workers in Developing Countries. NEJM
345: 538-541
[Full Text]
Tan, L., Hawk III, J. C., Sterling, M. L., for the Council on Scientific Affairs, American Me,
(2001). Report of the Council on Scientific Affairs: Preventing Needlestick Injuries in Health Care Settings. Arch Intern Med
161: 929-936
[Abstract][Full Text]
Fletcher, C. E.
(2000). Accurate Data: An Essential Component in Reducing Needlestick Injuries. Policy Politics Nursing Practice
1: 316-324
[Abstract]
Ross, R. S., Viazov, S., Roggendorf, M.
(2000). Risk of Hepatitis C Transmission From Infected Medical Staff to Patients: Model-Based Calculations for Surgical Settings. Arch Intern Med
160: 2313-2316
[Abstract][Full Text]
Beltrami, E. M., Williams, I. T., Shapiro, C. N., Chamberland, M. E.
(2000). Risk and Management of Blood-Borne Infections in Health Care Workers. Clin. Microbiol. Rev.
13: 385-407
[Abstract][Full Text]
Bliss, D. Z., Dysart, M.
(1999). Techniques and Procedures: Using Needleless Intravenous Access Devices for Administering Total Parenteral Nutrition (TPN): Practice Update. Nutr Clin Pract
14: 299-303
[Abstract]
(1997). Evaluation of Safety Devices for Preventing Percutaneous Injuries Among Health-Care Workers During Phlebotomy Procedures--Minneapolis-St Paul, New York City, and San Francisco, 1993-1995. JAMA
277: 449-450
[Abstract]
Tereskerz, P. M., Pearson, R. D., Jagger, J.
(1996). Occupational Exposure to Blood among Medical Students. NEJM
335: 1150-1153
[Full Text]
Lurie, P., Avins, A. L., Phillips, K. A., Kahn, J. G., Lowe, R. A., Ciccarone, D.
(1994). The Cost-effectiveness of Voluntary Counseling and Testing of Hospital Inpatients for HIV Infection. JAMA
272: 1832-1838
[Abstract]
Ippolito, G., De Carli, G., Puro, V., Petrosillo, N., Arici, C., Bertucci, R., Bianciardi, L., Bonazzi, L., Cestrone, A., Daglio, M., Desperati, M., Francesconi, M., Migliori, M., Monti, A., Perna, M. C., Pietrobon, F., Jagger, J.
(1994). Device-Specific Risk of Needlestick Injury in Italian Health Care Workers. JAMA
272: 607-610
[Abstract]
Parenti, C. M., Lederle, F. A., Impola, C. L., Peterson, L. R.
(1994). Reduction of Unnecessary Intravenous Catheter Use: Internal Medicine House Staff Participate in a Successful Quality Improvement Project. Arch Intern Med
154: 1829-1832
[Abstract]
Ippolito, G., Puro, V., Carli, G. D., the Italian Study Group on Occupational Risk of HI,
(1993). The Risk of Occupational Human Immunodeficiency Virus Infection in Health Care Workers: Italian Multicenter Study. Arch Intern Med
153: 1451-1458
[Abstract]
O'Neill, T. M., Abbott, A. V., Radecki, S. E.
(1992). Risk of Needlesticks and Occupational Exposures Among Residents and Medical Students. Arch Intern Med
152: 1451-1456
[Abstract]
Lederle, F. A., Parenti, C. M., Berskow, L. C., Ellingson, K. J.
(1992). The Idle Intravenous Catheter. ANN INTERN MED
116: 737-738
[Abstract]
Lo, B., Steinbrook, R.
(1992). Health Care Workers Infected With the Human Immunodeficiency Virus: The Next Steps. JAMA
267: 1100-1105
[Abstract]
Perry, S., Ryan, J., Polan, H. J.
(1992). Needlestick Injury Associated With Venipuncture. JAMA
267: 54-54
[Abstract]
Jagger, J., Pearson, R. D.
(1991). Do Universal Precautions Reduce Needlestick Injuries?. JAMA
266: 359-360
[Abstract]
Waters, B. L.
(1991). Inoculating Blood Cultures: Recapping Needles and Contamination Rates. JAMA
265: 1685-1686
[Abstract]
Wong, E. S., Stotka, J. L., Chinchilli, V. M., Williams, D. S., Stuart, C. G., Markowitz, S. M.
(1991). Are Universal Precautions Effective in Reducing the Number of Occupational Exposures Among Health Care Workers? A Prospective Study of Physicians on a Medical Service. JAMA
265: 1123-1128
[Abstract]
Satterfield, D., Kling, J.
(1991). Professional Development: Diabetes Educators Encourage Safe Needle Practice. The Diabetes Educator
17: 321-325
Leisure, M. K., Moore, D. M., Schwartzman, J. D., Hayden, G. F., Donowitz, L. G.
(1990). Changing the Needle When Inoculating Blood Cultures: A No-Benefit and High-Risk Procedure. JAMA
264: 2111-2112
[Abstract]
Krumholz, H. M., Cummings, S., York, M.
(1990). Blood Culture Phlebotomy: Switching Needles Does Not Prevent Contamination. ANN INTERN MED
113: 290-292
[Abstract]