The risk of transmission of the human immunodeficiency virus to recipients of blood transfusions exists chiefly during the period between the time a donor is infected and the time he or she has a positive blood test for HIV antibodies. Estimating the chance that blood will be donated during this period is an effective way to define the risk of HIV infection from transfusion. Using this approach, and employing data from over 17 million American Red Cross blood donations, we estimate that during 1987 the most likely number of units of blood infected with undetected HIV that were transfused was 131 (range, 67 to 227). For a patient, the odds of contracting HIV infection were 1:153,000 per unit transfused. A patient who received the average transfusion (5.4 units) had odds of 1:28,000. The risk has been decreasing by more than 30 percent a year. We estimate that donor-recruitment practices plus careful education and screening are eliminating 49 of every 50 donors likely to be HIV-positive and that testing is 92 to 97 percent effective, for a combined effectiveness of 99.9 percent. The risk of undetected infectious units can probably be further reduced by transfusing fewer units and units from fewer donors, recruiting more women and fewer men as new donors, and encouraging more frequent donations from donors who have been tested repeatedly.
Source Information
Blood Services, National Headquarters, American Red Cross, Washington, D.C.
This article has been cited by other articles:
Weber, B., Berger, A., Rabenau, H., Doerr, H. W.
(2002). Evaluation of a New Combined Antigen and Antibody Human Immunodeficiency Virus Screening Assay, VIDAS HIV DUO Ultra. J. Clin. Microbiol.
40: 1420-1426
[Abstract][Full Text]
Sanchez, A. M., Schreiber, G. B., Bethel, J., McCurdy, P. R., Glynn, S. A., Williams, A. E., Gilcher, R., for the Retrovirus Epidemiology Donor Study,
(2001). Prevalence, Donation Practices, and Risk Assessment of Blood Donors With Hemochromatosis. JAMA
286: 1475-1481
[Abstract][Full Text]
Glynn, S. A., Kleinman, S. H., Schreiber, G. B, Busch, M. P., Wright, D. J., Smith, J. W., Nass, C. C., Williams, A. E., for the Retrovirus Epidemiology Donor Study,
(2000). Trends in Incidence and Prevalence of Major Transfusion-Transmissible Viral Infections in US Blood Donors, 1991 to 1996. JAMA
284: 229-235
[Abstract][Full Text]
Katzenstein, T. L., Dickmeiss, E., Aladdin, H., Hede, A., Nielsen, C., Nielsen, H., Jorgensen, L. B., Gerstoft, J.
(2000). Failure To Develop HIV Infection after Receipt of HIV-Contaminated Blood and Postexposure Prophylaxis. ANN INTERN MED
133: 31-34
[Abstract][Full Text]
Weber, B., Mbargane Fall, E. H., Berger, A., Doerr, H. W.
(1998). Reduction of Diagnostic Window by New Fourth-Generation Human Immunodeficiency Virus Screening Assays. J. Clin. Microbiol.
36: 2235-2239
[Abstract][Full Text]
KEATING, E. M.
(1998). Instructional Course Lectures, The American Academy of Orthopaedic Surgeons - Current Options and Approaches for Blood Management in Orthopaedic Surgery*{{dagger}}. JBJS
80: 750-62
[Full Text]
Litvak, E., Siegel, J. E., Pauker, S. G., Lallemant, M., Fineberg, H. V., Weinstein, M. C.
(1997). Whose Blood Is Safer?: The Effect of the Stage of the Epidemic on Screening for HIV. Med Decis Making
17: 455-463
[Abstract]
Schreiber, G. B., Busch, M. P., Kleinman, S. H., Korelitz, J. J., The Retrovirus Epidemiology Donor Study,
(1996). The Risk of Transfusion-Transmitted Viral Infections. NEJM
334: 1685-1690
[Abstract][Full Text]
Lackritz, E. M., Satten, G. A., Aberle-Grasse, J., Dodd, R. Y., Raimondi, V. P., Janssen, R. S., Lewis, W. F., Notari, E. P., Petersen, L. R.
(1995). Estimated Risk of Transmission of the Human Immunodeficiency Virus by Screened Blood in the United States. NEJM
333: 1721-1725
[Abstract][Full Text]
Sloand, E. M., Pitt, E., Klein, H. G.
(1995). Safety of the Blood Supply. JAMA
274: 1368-1373
[Abstract]
Svensson, L. G., Sun, J., Nadolny, E., Kimmel, W. A.
(1995). Prospective Evaluation of Minimal Blood Use for Ascending Aorta and Aortic Arch Operations. Ann. Thorac. Surg.
59: 1501-1508
[Abstract][Full Text]
Etchason, J., Petz, L., Keeler, E., Calhoun, L., Kleinman, S., Snider, C., Fink, A., Brook, R.
(1995). The Cost Effectiveness of Preoperative Autologous Blood Donations. NEJM
332: 719-724
[Abstract][Full Text]
Goodnough, L. T., Bodner, M. S., Martin, J. W.
(1994). Blood Transfusion and Blood Conservation: Cost and Utilization Issues. American Journal of Medical Quality
9: 172-183
[Abstract]
AuBuchon, J. P., Birkmeyer, J. D.
(1994). Safety and Cost-effectiveness of Solvent-Detergent--Treated Plasma: In Search of a Zero-Risk Blood Supply. JAMA
272: 1210-1214
[Abstract]
Fox, M. A, Kent, A. P, Fraser, S. R, Wilkins, K. M, Kendall, K. N
(1993). Filtration of shed mediastinal blood. Perfusion
8: 331-336
[Abstract]
McCullough, J.
(1993). The Nation's Changing Blood Supply System. JAMA
269: 2239-2245
[Abstract]
Heymann, S. J., Brewer, T. F., Fineberg, H. V., Wilson, M. E.
(1992). How Safe Is Safe Enough? New Infections and the U.S. Blood Supply. ANN INTERN MED
117: 612-614
[Abstract]
Sloand, E. M., Pitt, E., Chiarello, R. J., Nemo, G. J.
(1991). HIV Testing: State of the Art. JAMA
266: 2861-2866
[Abstract]
KRIEGER, M. S., KRIEGER, J. N.
(1991). Human Immunodeficiency Virus: Occupational Risk for Surgeons. Arch Surg
126: 789-789
[Abstract]
Klein, R. S., Friedland, G. H.
(1990). Transmission of Human Immunodeficiency Virus Type 1 (HIV-1) by Exposure to Blood: Defining the Risk. ANN INTERN MED
113: 729-730
[Abstract]
Reddy, D. J., Ryan, C. J., Shepard, A. D., Johnson, C. C., Elliott, J. P. Jr, Smith, R. F., Ernst, C. B.
(1990). Intraoperative Autotransfusion in Vascular Surgery. Arch Surg
125: 1012-1016
[Abstract]
Nelson, K. E., Vlahov, D., Margolick, J., Bernal, M., Taylor, E.
(1990). Blood and Plasma Donations Among a Cohort of Intravenous Drug Users. JAMA
263: 2194-2197
[Abstract]
(1989). HIV INFECTION VIA TRANSFUSION IS RARE, BUT OUTCOME IS DIRE. JWatch General
1989: 2-2
[Full Text]