Background The treatment of aortic aneurysms with endovascularstents or stentgraft prostheses is receiving increasingattention as an alternative to major abdominal surgery. To definethe clinical value of this technique, we prospectively studiedthe use of stentgraft endoprostheses made of nitinoland covered with polyester fabric for the treatment of infrarenalabdominal aortic aneurysms.
Methods We treated a total of 154 patients at three academichospitals. Twenty-one patients with aortic aneurysms not involvingthe aortic bifurcation received straight stentgrafts,and 133 patients with aortic aneurysms involving the bifurcationand the common iliac arteries received bifurcated stentgrafts.After a unilateral surgical arteriotomy, the endoprostheseswere advanced through the femoral arteries and placed underfluoroscopic guidance. Computed tomography and intraarterialangiography were performed during an average follow-up of 12.5months.
Results The primary success rate, defined as complete exclusionof the abdominal aortic aneurysm from the circulation, was 86percent in the group receiving straight grafts and 87 percentin the group receiving bifurcated grafts. In three patientsthe procedure had to be converted to an open surgical operation.Minor (n = 13) or major (n = 3) complications associated withthe procedure (including 1 death) occurred in 10 percent ofthe patients. All patients had a postimplantation syndrome,with leukocytosis and elevated C-reactive protein levels.
Conclusions Our results suggest that endovascular treatmentof infrarenal abdominal aortic aneurysms is technically feasibleand can effectively exclude abdominal aortic aneurysms fromthe circulation. With further refinement, endoluminal repairmay emerge as an interventional strategy to treat infrarenalaortic aneurysms, especially in patients at high surgical risk.
Source Information
From the Departments of Diagnostic Radiology (U.B., M.L.) and Cardiovascular Surgery (F.B., G.S.), University Hospital, Freiburg, Germany; the Departments of Radiology (G.V., D.T.) and Surgery (G.N.), Henriettenstiftung, Hannover, Germany; and the Departments of Angiography and Interventional Radiology (J.L., S.T.) and Vascular Surgery (G.K., P.P., T.H.), University Hospital, Vienna, Austria.
Address reprint requests to Dr. Blum at the Department of Diagnostic Radiology, University Hospital Freiburg, Hugstetter Str. 55, D-79106 Freiburg, Germany.
Infrarenal Aortic Aneurysms
Matsumura J. S., Pearce W. H., Yusuf S. W., Wenham P., Hopkinson B. R., Hoch R. C., Blum U., Beyersdorf F., Ernst C. B.
Extract |
Full Text
N Engl J Med 1997;
336:1756-1758, Jun 12, 1997.
Correspondence
This article has been cited by other articles:
Hong, C., Heiken, J. P., Sicard, G. A., Pilgram, T. K., Bae, K. T.
(2008). Clinical Significance of Endoleak Detected on Follow-Up CT After Endovascular Repair of Abdominal Aortic Aneurysm. Am. J. Roentgenol.
191: 808-813
[Abstract][Full Text]
Holfeld, J., Gottardi, R., Zimpfer, D., Dorfmeister, M., Dumfarth, J., Funovics, M., Schoder, M., Weigang, E., Lammer, J., Wolner, E., Czerny, M., Grimm, M.
(2008). Treatment of symptomatic coral reef aorta by endovascular stent-graft placement.. Ann. Thorac. Surg.
85: 1817-1819
[Abstract][Full Text]
Rowlands, T. E., Homer-Vanniasinkam, S.
(2007). Paradoxical Neutrophil Elastase Release in Endovascular Abdominal Aortic Aneurysm Repair. VASC ENDOVASCULAR SURG
41: 48-54
[Abstract]
Leurs, L. J., Buth, J., Laheij, R. J. F., for the EUROSTAR Collaborators,
(2007). Long-term Results of Endovascular Abdominal Aortic Aneurysm Treatment With the First Generation of Commercially Available Stent Grafts. Arch Surg
142: 33-41
[Abstract][Full Text]
Norwood, M G A, Lloyd, G M, Bown, M J, Fishwick, G, London, N J, Sayers, R D
(2007). Endovascular abdominal aortic aneurysm repair. Postgrad. Med. J.
83: 21-27
[Abstract][Full Text]
Yang, J., Zuo, J., Yang, L., Duan, W., Xiong, L., Zheng, M., Cui, H., Yi, D.
(2006). Endovascular stent-graft treatment of thoracic aortic dissection. ICVTS
5: 688-691
[Abstract][Full Text]
Gerasimidis, T., Sfyroeras, G., Trellopoulos, G., Skoura, L., Papazoglou, K., Konstantinidis, K., Karamanos, D., Filaktou, A., Parapanisiou, E.
(2005). Impact of Endograft Material on the Inflammatory Response After Elective Endovascular Abdominal Aortic Aneurysm Repair. ANGIOLOGY
56: 743-753
[Abstract]
Duebener, L. F., Lorenzen, P., Richardt, G., Misfeld, M., Notzold, A., Hartmann, F., Sievers, H.-H., Geist, V.
(2004). Emergency Endovascular Stent-Grafting for Life-Threatening Acute Type B Aortic Dissections. Ann. Thorac. Surg.
78: 1261-1266
[Abstract][Full Text]
Elkouri, S., Martelli, E., Gloviczki, P., McKusick, M. A., Panneton, J. M., Andrews, J. C., Noel, A. A., Bower, T. C., Sullivan, T. M., Rowland, C., Hoskin, T. L., Cherry, K. J.
(2004). Most Patients with Abdominal Aortic Aneurysm Are Not Suitable for Endovascular Repair Using Currently Approved Bifurcated Stent-Grafts. VASC ENDOVASCULAR SURG
38: 401-412
[Abstract]
Nataraj, V, Mortimer, A.
(2004). Endovascular abdominal aortic aneurysm repair. Contin Educ Anaesth Crit Care Pain
4: 91-94
[Abstract][Full Text]
Sato, Y., Kimura, T., Sato, E., Nishiwaki, K., Shimada, Y.
(2003). Severe bradycardia in a patient undergoing endovascular stent-graft repair for abdominal aortic aneurysm with vena cava balloon occlusion. Canadian J. Anesthesia
50: 970-971
[Full Text]
Santamore, D. C., Saldanha, C. L., Santamore, W. P.
(2003). Endovascular Repair of the Abdominal Aortic Aneurysm. SEMIN CARDIOTHORAC VASC ANESTH
7: 213-222
[Abstract]
Rozenblit, A. M., Patlas, M., Rosenbaum, A. T., Okhi, T., Veith, F. J., Laks, M. P., Ricci, Z. J.
(2003). Detection of Endoleaks after Endovascular Repair of Abdominal Aortic Aneurysm: Value of Unenhanced and Delayed Helical CT Acquisitions. Radiology
227: 426-433
[Abstract][Full Text]
Schoder, M., Cartes-Zumelzu, F., Grabenwoger, M., Cejna, M., Funovics, M., Krenn, C. G., Hutschala, D., Wolf, F., Thurnher, S., Kretschmer, G., Lammer, J.
(2003). Elective Endovascular Stent-Graft Repair of Atherosclerotic Thoracic Aortic Aneurysms:Clinical Results and Midterm Follow-Up. Am. J. Roentgenol.
180: 709-715
[Abstract][Full Text]
Maldonado, T. S., Gagne, P. J.
(2003). Controversies in the Management of Type 11 "Branch" Endoleaks Following Endovascular Abdominal Aortic Aneurysm Repair. VASC ENDOVASCULAR SURG
37: 1-12
[Abstract]
Moffatt, S. D., Mitchell, R. S.
(2003). Endovascular Stent Management of Thoracic Aneurysms and Dissections. Card Surg Adult
2: 1191-1204
[Full Text]
Teufelsbauer, H., Prusa, A. M., Wolff, K., Polterauer, P., Nanobashvili, J., Prager, M., Holzenbein, T., Thurnher, S., Lammer, J., Schemper, M., Kretschmer, G., Huk, I.
(2002). Endovascular Stent Grafting Versus Open Surgical Operation in Patients With Infrarenal Aortic Aneurysms: A Propensity Score-Adjusted Analysis. Circulation
106: 782-787
[Abstract][Full Text]
Lachat, M., Pfammatter, T., Witzke, H., Bernard, E., Wolfensberger, U., Kunzli, A., Turina, M.
(2002). Acute traumatic aortic rupture: early stent-graft repair. Eur. J. Cardiothorac. Surg.
21: 959-963
[Abstract][Full Text]
Hutschala, D., Fleck, T., Czerny, M., Ehrlich, M., Schoder, M., Lammer, J., Wolner, E., Grabenwoger, M.
(2002). Endoluminal stent-graft placement in patients with acute aortic dissection type B. Eur. J. Cardiothorac. Surg.
21: 964-969
[Abstract][Full Text]
Golzarian, J., Murgo, S., Dussaussois, L., Guyot, S., Said, K. A., Wautrecht, J. C., Struyven, J.
(2002). Evaluation of Abdominal Aortic Aneurysm After Endoluminal Treatment: Comparison of Color Doppler Sonography with Biphasic Helical CT. Am. J. Roentgenol.
178: 623-628
[Abstract][Full Text]
Quinn, S. F., Kim, J., Sheley, R. C., Demlow, T. A., Zelko, J.
(2002). Percutaneous Deployment of a Low-Profile Bifurcated Stent-Graft. Am. J. Roentgenol.
178: 654-656
[Full Text]
Howell, M. H., Strickman, N., Mortazavi, A., Hallman, C. H., Krajcer, Z.
(2001). Preliminary results of endovascular abdominal aortic aneurysm exclusion with the AneuRx stent-graft. J Am Coll Cardiol
38: 1040-1046
[Abstract][Full Text]
White, C. J
(2001). Non-surgical treatment of patients with peripheral vascular disease. Br Med Bull
59: 173-192
[Abstract][Full Text]
Sangiorgi, G., D'Averio, R., Mauriello, A., Bondio, M., Pontillo, M., Castelvecchio, S., Trimarchi, S., Tolva, V., Nano, G., Rampoldi, V., Spagnoli, L. G., Inglese, L.
(2001). Plasma Levels of Metalloproteinases-3 and -9 as Markers of Successful Abdominal Aortic Aneurysm Exclusion After Endovascular Graft Treatment. Circulation
104: I-288-295
[Abstract][Full Text]
Schoder, M., Zaunbauer, L., Holzenbein, T., Fleischmann, D., Cejna, M., Kretschmer, G., Thurnher, S., Lammer, J.
(2001). Internal Iliac Artery Embolization Before Endovascular Repair of Abdominal Aortic Aneurysms: Frequency, Efficacy, and Clinical Results. Am. J. Roentgenol.
177: 599-605
[Abstract][Full Text]
Bosch, J. L., Beinfeld, M. T., Halpern, E. F., Lester, J. S., Gazelle, G. S.
(2001). Endovascular versus Open Surgical Elective Repair of Infrarenal Abdominal Aortic Aneurysm: Predictors of Patient Discharge Destination. Radiology
220: 576-580
[Abstract][Full Text]
Bosch, J. L., Lester, J. S., McMahon, P. M., Beinfeld, M. T., Halpern, E. F., Kaufman, J. A., Brewster, D. C., Gazelle, G. S.
(2001). Hospital Costs for Elective Endovascular and Surgical Repairs of Infrarenal Abdominal Aortic Aneurysms. Radiology
220: 492-497
[Abstract][Full Text]
Silberzweig, J. E., Marin, M. L., Hollier, L. H., Mitty, H. A., Connelly, T. L.
(2001). Balloon-Expandable Common Iliac Artery Occluder Device for Endovascular Aneurysm Repair. VASC ENDOVASCULAR SURG
35: 263-271
[Abstract]
Sawhney, R., Kerlan, R. K., Wall, S. D., Chuter, T. A. M., Ruiz, D. E., Canto, C. J., LaBerge, J. M., Reilly, L. M., Yee, J., Wilson, M. W., Jean-Claude, J., Faruqi, R. M., Gordon, R. L.
(2001). Analysis of Initial CT Findings after Endovascular Repair of Abdominal Aortic Aneurysm. Radiology
220: 157-160
[Abstract][Full Text]
Görich, J., Rilinger, N., Sokiranski, R., Söldner, J., Kaiser, W., Krämer, S., Ermis, C., Schütz, A., Sunder-Plassmann, L., Pamler, R.
(2001). Endoleaks after Endovascular Repair of Aortic Aneurysm: Are They Predictable?--Initial Results. Radiology
218: 477-480
[Abstract][Full Text]
Zaugg, M., Lachat, M. L., Pfammatter, T., Cathomas, G., Schmid, E. R.
(2001). Sudden Respiratory Arrest Resulting From Brainstem Embolism in a Patient Undergoing Endovascular Abdominal Aortic Aneurysm Repair. Anesth. Analg.
92: 335-337
[Abstract][Full Text]
Yano, O. J., Marin, M. L., Hollier, L.
(2001). Endovascular Options in the Management of Complex Aortic Problems. PERSPECT VASC SURG ENDOVASC THER
14: 1-12
[Abstract]
Storck, M., Scharrer-Pamler, R., X, K., Gallmeier, U., Gorich, J., Sunder-Plassmann, L., Bruckner, U., Mickley, V.
(2001). Does a Postimplantation Syndrome Following Endovascular Treatment of Aortic Aneurysms Exist?. VASC ENDOVASCULAR SURG
35: 23-29
[Abstract]
Czermak, B. V., Waldenberger, P., Fraedrich, G., Dessl, A. H., Roberts, K. E., Bale, R. J., Perkmann, R., Jaschke, W. R.
(2000). Treatment of Stanford Type B Aortic Dissection with Stent-Grafts: Preliminary Results. Radiology
217: 544-550
[Abstract][Full Text]
Lammer, J., Dake, M. D., Bleyn, J., Katzen, B. T., Cejna, M., Piquet, P., Becker, G. J., Settlage, R. A.
(2000). Peripheral Arterial Obstruction: Prospective Study of Treatment with a Transluminally Placed Self-expanding Stent-Graft. Radiology
217: 95-104
[Abstract][Full Text]
Kaufman, J. A., Geller, S. C., Brewster, D. C., Fan, C.-M., Cambria, R. P., LaMuraglia, G. M., Gertler, J. P., Abbott, W. M., Waltman, A. C.
(2000). Endovascular Repair of Abdominal Aortic Aneurysms: Current Status and Future Directions. Am. J. Roentgenol.
175: 289-302
[Full Text]
Görich, J., Rilinger, N., Sokiranski, R., Krämer, S. C., Ermis, C., Schütz, A., Brambs, H.-J., Söldner, J., Kaiser, W., Sunder-Plassmann, L., Pamler, R.
(2000). Treatment of Leaks after Endovascular Repair of Aortic Aneurysms. Radiology
215: 414-420
[Abstract][Full Text]
Ishiguchi, T., Nishikimi, N., Usui, A., Ishigaki, T.
(2000). Endovascular Stent-Graft Deployment: Temporary Vena Caval Occlusion with Balloons to Control Aortic Blood Flow-Experimental Canine Study and Initial Clinical Experience. Radiology
215: 594-599
[Abstract][Full Text]
Doenst, T., Schlensak, C., Beyersdorf, F., Rousseau, H., Janne d’Othee, B., Perreault, P., Meites, G., Joffre, F., Otal, P., Soula, P., Concina, P., Massabuau, P., Mazerolles, M., Bui, B.
(2000). Limitations to the Therapeutic Potential of Endoluminal Stent Placement in the Thoracic Aorta • Response. Circulation
101
: e96-e96
[Full Text]
Gorich, J., Rilinger, N., Kramer, S., Sokiranski, R., Pamler, R., Ermis, C., Kapfer, X.
(2000). Angiography of Leaks After Endovascular Repair of Infrarenal Aortic Aneurysms. Am. J. Roentgenol.
174: 811-814
[Abstract][Full Text]
Makaroun, M., Zajko, A.
(2000). Endoleaks Following Endovascular Aortic Aneurysm Repair: Clinical Significance and Treatment Modalities. PERSPECT VASC SURG ENDOVASC THER
13: 1-14
[Abstract]
Bali, H. K, Jain, A. K
(1999). Takayasu's Arteritis: Current Status of Angioplasty and Stenting. Asian Cardiovasc. Thorac. Ann.
7: 339-344
[Abstract][Full Text]
Haskal, Z. J., Brennecke, L. H.
(1999). Transjugular Intrahepatic Portosystemic Shunts Formed with Polyethylene Terephthalate-covered Stents: Experimental Evaluation in Pigs. Radiology
213: 853-859
[Abstract][Full Text]
Inoue, K., Hosokawa, H., Iwase, T., Sato, M., Yoshida, Y., Ueno, K., Tsubokawa, A., Tanaka, T., Tamaki, S., Suzuki, T.
(1999). Aortic Arch Reconstruction by Transluminally Placed Endovascular Branched Stent Graft. Circulation
100: II-316-321
[Abstract][Full Text]
Smith, B. M., Gray, R. J., Laird, J. R., Kohlman-Trigoboff, D., Deforty, D., Stanford, J. L.
(1999). Management of the Femoral Artery After Transluminal Repair of Abdominal Aortic Aneurysms. VASC ENDOVASCULAR SURG
33: 589-593
[Abstract]
Nienaber, C. A., Fattori, R., Lund, G., Dieckmann, C., Wolf, W., von Kodolitsch, Y., Nicolas, V., Pierangeli, A.
(1999). Nonsurgical Reconstruction of Thoracic Aortic Dissection by Stent-Graft Placement. NEJM
340: 1539-1545
[Abstract][Full Text]
Dake, M. D., Kato, N., Mitchell, R. S., Semba, C. P., Razavi, M. K., Shimono, T., Hirano, T., Takeda, K., Yada, I., Miller, D. C.
(1999). Endovascular Stent-Graft Placement for the Treatment of Acute Aortic Dissection. NEJM
340: 1546-1552
[Abstract][Full Text]
Rousseau, H., Soula, P., Perreault, P., Bui, B., d'Othee, B. J., Massabuau, P., Meites, G., Concina, P., Mazerolles, M., Joffre, F., Otal, P.
(1999). Delayed Treatment of Traumatic Rupture of the Thoracic Aorta With Endoluminal Covered Stent. Circulation
99: 498-504
[Abstract][Full Text]
Svensson, L. G., Cambria, R. P.
(1998). Expanding Surgical Options Using Minimally Invasive Techniques for Cardio-aortic and Aortic Procedures. Arch Surg
133: 1160-1165
[Abstract][Full Text]
Goldman, L.
(1998). A 75-Year-Old Woman With an Abdominal Aortic Aneurysm and Emphysema. JAMA
280: 366-372
[Full Text]
Ahn, S. S., Obrand, D. I.
(1998). Current Status of Intraluminal Grafts for Aortic Aneurysms. VASC ENDOVASCULAR SURG
32: 215-219
Matsumura, J. S., Pearce, W. H., Yusuf, S. W., Wenham, P., Hopkinson, B. R., Hoch, R. C., Blum, U., Beyersdorf, F., Ernst, C. B.
(1997). Infrarenal Aortic Aneurysms. NEJM
336: 1756-1758
[Full Text]
(1997). ENDOVASCULAR STENT-GRAFTS FOR ABDOMINAL AORTIC ANEURYSMS. JWatch General
1997: 4-4
[Full Text]
Ernst, C. B.
(1997). Current Therapy for Infrarenal Aortic Aneurysms. NEJM
336: 58-60
[Full Text]
Pitton, M. B., Schmenger, R. P., Neufang, A., Konerding, M. A., Duber, C., Thelen, M.
(2002). Endovascular Aneurysm Repair: Magnetic Resonance Monitoring of Histological Organization Processes in the Excluded Aneurysm. Circulation
105: 1995-1999
[Abstract][Full Text]