Congestive heart failure affects about 1 percent of adults inthe United States1 and is a contributing factor in over 250,000deaths annually.2 It is diagnosed in 400,000 Americans eachyear3 and is the primary diagnosis for over 900,000 hospitalizationsper year.4
In 1990 the age-adjusted death rate from congestive heart failurewas 106.4 per 100,000,5 more than that from breast cancer andthe acquired immunodeficiency syndrome combined.6,7 The mediansurvival after diagnosis is 1.7 years in men and 3.2 years inwomen, with a 5-year survival rate of less than 50 percent.8Even though medical therapies have improved survival . . . [Full Text of this Article]
Ventricular Assist Devices
A Historical Perspective
Wearable Left Ventricular Assist Devices
Left Ventricular Assist Devices as a Bridge to Transplantation
Selection of Patients
Cardiac Factors Affecting Selection
Valvular Heart Disease
Coronary Artery Disease
Arrhythmias
Congenital Defects
Extracardiac Factors Affecting Selection
Interactions between the Patient and the Device
Patients' Adaptation to the Device
Complications
Bleeding
Right-Sided Heart Failure
Thromboembolism
Infection
Device Malfunction
Other Complications
Future Directions
Source Information
From the Department of Surgery, Division of Cardiothoracic Surgery, ColumbiaPresbyterian Medical Center, College of Physicians and Surgeons, Columbia University, New York.
Address reprint requests to Dr. Rose at the Department of Surgery, Milstein Hospital, 177 Fort Washington Ave., New York, NY 10032.
References
This article has been cited by other articles:
Schaffer, J. M., Allen, J. G., Weiss, E. S., Patel, N. D., Russell, S. D., Shah, A. S., Conte, J. V.
(2009). Evaluation of risk indices in continuous-flow left ventricular assist device patients.. Ann. Thorac. Surg.
88: 1889-1896
[Abstract][Full Text]
John, R., Panch, S., Hrabe, J., Wei, P., Solovey, A., Joyce, L., Hebbel, R.
(2009). Activation of endothelial and coagulation systems in left ventricular assist device recipients.. Ann. Thorac. Surg.
88: 1171-1179
[Abstract][Full Text]
Raman, S. V., Tran, T., Simonetti, O. P., Sun, B.
(2009). Dynamic computed tomography to determine cardiac output in patients with left ventricular assist devices.. J. Thorac. Cardiovasc. Surg.
137: 1213-1217
[Abstract][Full Text]
Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., Michl, K., Oates, J. A., Rahko, P. S., Silver, M. A., Stevenson, L. W., Yancy, C. W.
(2009). 2009 Focused Update Incorporated Into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults: A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines Developed in Collaboration With the International Society for Heart and Lung Transplantation. J Am Coll Cardiol
53: e1-e90
[Full Text]
2005 WRITING COMMITTEE MEMBERS, , Hunt, S. A., Abraham, W. T., Chin, M. H., Feldman, A. M., Francis, G. S., Ganiats, T. G., Jessup, M., Konstam, M. A., Mancini, D. M., Michl, K., Oates, J. A., Rahko, P. S., Silver, M. A., Stevenson, L. W., Yancy, C. W.
(2009). 2009 Focused Update Incorporated Into the ACC/AHA 2005 Guidelines for the Diagnosis and Management of Heart Failure in Adults: A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines: Developed in Collaboration With the International Society for Heart and Lung Transplantation. Circulation
119: e391-e479
[Full Text]
Fitzpatrick, J. R. III, Frederick, J. R., Hiesinger, W., Hsu, V. M., McCormick, R. C., Kozin, E. D., Laporte, C. M., O'Hara, M. L., Howell, E., Dougherty, D., Cohen, J. E., Southerland, K. W., Howard, J. L., Paulson, E. C., Acker, M. A., Morris, R. J., Woo, Y. J.
(2009). Early planned institution of biventricular mechanical circulatory support results in improved outcomes compared with delayed conversion of a left ventricular assist device to a biventricular assist device. J. Thorac. Cardiovasc. Surg.
137: 971-977
[Abstract][Full Text]
Patel, N. D., Weiss, E. S., Schaffer, J., Ullrich, S. L., Rivard, D. C., Shah, A. S., Russell, S. D., Conte, J. V.
(2008). Right Heart Dysfunction After Left Ventricular Assist Device Implantation: A Comparison of the Pulsatile HeartMate I and Axial-Flow HeartMate II Devices. Ann. Thorac. Surg.
86: 832-840
[Abstract][Full Text]
Osaki, S., Edwards, N. M., Velez, M., Johnson, M. R., Murray, M. A., Hoffmann, J. A., Kohmoto, T.
(2008). Improved survival in patients with ventricular assist device therapy: the University of Wisconsin experience.. Eur. J. Cardiothorac. Surg.
34: 281-288
[Abstract][Full Text]
Guha, A., Munjampalli, S., Bandi, V., Loebe, M., Noon, G., Lunn, W.
(2008). Pleural Effusion After Ventricular Assist Device Placement: Prevalence and Pleural Fluid Characteristics. Chest
134: 382-386
[Abstract][Full Text]
Mau, J., Menzie, S., Ward, M., Bundgaard, H., Hunyor, S.
(2007). Time-dependent response of both ventricles after septal ablation: Implications for biventricular support after left ventricular assist device placement. J. Thorac. Cardiovasc. Surg.
134: 579-586
[Abstract][Full Text]
Thiele, H., Smalling, R. W., Schuler, G. C.
(2007). Percutaneous left ventricular assist devices in acute myocardial infarction complicated by cardiogenic shock. Eur Heart J
28: 2057-2063
[Abstract][Full Text]
Drakos, S. G., Kfoury, A. G., Long, J. W., Stringham, J. C., Gilbert, E. M., Horne, B. D., Hagan, M.-B. E., Nelson, K., Renlund, D. G.
(2007). Similar transplantation outcomes in patients bridged with cardiac assist devices for acute cardiogenic shock versus chronic heart failure. Eur J Heart Fail
9: 845-849
[Abstract][Full Text]
Feller, E. D., Sorensen, E. N., Haddad, M., Pierson, R. N., Johnson, F. L., Brown, J. M., Griffith, B. P.
(2007). Clinical Outcomes Are Similar in Pulsatile and Nonpulsatile Left Ventricular Assist Device Recipients. Ann. Thorac. Surg.
83: 1082-1088
[Abstract][Full Text]
Westaby, S., Poole-Wilson, P.
(2007). Mechanical circulatory support in the UK. BMJ
334: 167-168
[Full Text]
Petrucci, R. J., Truesdell, K. C., Carter, A., Goldstein, N. E., Russell, M. M., Dilkes, D., Fitzpatrick, J. M., Thomas, C. E., Keenan, M. E., Lazarus, L. A., Chiaravalloti, N. D., Trunzo, J. J., Verjans, J. W., Holmes, E. C., Samuels, L. E., Narula, J.
(2006). Cognitive dysfunction in advanced heart failure and prospective cardiac assist device patients.. Ann. Thorac. Surg.
81: 1738-1744
[Abstract][Full Text]
Dang, N. C., Naka, Y.
(2006). Reply to the Editor. J. Thorac. Cardiovasc. Surg.
131: 1212-1212
[Full Text]
Liang, H., Lin, H., Weng, Y., Dandel, M., Hetzer, R.
(2005). Prediction of cardiac function after weaning from ventricular assist devices. J. Thorac. Cardiovasc. Surg.
130: 1555-1560
[Abstract][Full Text]
Wohlschlaeger, J., Schmitz, K. J., Schmid, C., Schmid, K. W., Keul, P., Takeda, A., Weis, S., Levkau, B., Baba, H. A.
(2005). Reverse remodeling following insertion of left ventricular assist devices (LVAD): A review of the morphological and molecular changes. Cardiovasc Res
68: 376-386
[Abstract][Full Text]
Thoennissen, N. H., Schneider, M., Allroggen, A., Ritter, M., Dittrich, R., Schmid, C., Scheld, H. H., Ringelstein, E. B., Nabavi, D. G.
(2005). High level of cerebral microembolization in patients supported with the DeBakey left ventricular assist device. J. Thorac. Cardiovasc. Surg.
130: 1159-1166
[Abstract][Full Text]
El-Magharbel, I.
(2005). Ventricular Assist Devices and Anesthesia. SEMIN CARDIOTHORAC VASC ANESTH
9: 241-249
[Abstract]
DiMartini, A. F., Dew, M. A., Trzepacz, P. T.
(2005). Organ Transplantation. Focus
3: 280-303
[Full Text]
Goldstein, D. J., Zucker, M., Arroyo, L., Baran, D., McCarthy, P. M., Loebe, M., Noon, G. P.
(2005). Safety and feasibility trial of the MicroMed DeBakey ventricular assist device as a bridge to transplantation. J Am Coll Cardiol
45: 962-963
[Full Text]
Endorsed by the European Society of Intensive Care, , Authors/Task Force Members, , Nieminen, M. S., Bohm, M., Cowie, M. R., Drexler, H., Filippatos, G. S., Jondeau, G., Hasin, Y., Lopez-Sendon, J., Mebazaa, A., Metra, M., Rhodes, A., Swedberg, K., ESC Committee for Practice Guidelines, , Priori, S. G., Garcia, M. A. A., Blanc, J.-J., Budaj, A., Cowie, M. R, Dean, V., Deckers, J., Burgos, E. F., Lekakis, J., Lindahl, B., Mazzotta, G., Morais, J., Oto, A., Smiseth, O. A., Document Reviewers, , Garcia, M. A. A., Dickstein, K., Albuquerque, A., Conthe, P., Crespo-Leiro, M., Ferrari, R., Follath, F., Gavazzi, A., Janssens, U., Komajda, M., Morais, J., Moreno, R., Singer, M., Singh, S., Tendera, M., Thygesen, K.
(2005). Executive summary of the guidelines on the diagnosis and treatment of acute heart failure: The Task Force on Acute Heart Failure of the European Society of Cardiology. Eur Heart J
26: 384-416
[Full Text]
Park, S. J., Tector, A., Piccioni, W., Raines, E., Gelijns, A., Moskowitz, A., Rose, E., Holman, W., Furukawa, S., Frazier, O. H., Dembitsky, W.
(2005). Left ventricular assist devices as destination therapy: A new look at survival. J. Thorac. Cardiovasc. Surg.
129: 9-17
[Abstract][Full Text]
Horton, S. C., Khodaverdian, R., Powers, A., Revenaugh, J., Renlund, D. G., Moore, S. A., Rasmusson, B., Nelson, K. E., Long, J. W.
(2004). Left ventricular assist device malfunction: a systematic approach to diagnosis. J Am Coll Cardiol
43: 1574-1583
[Abstract][Full Text]
Darouiche, R. O.
(2004). Treatment of Infections Associated with Surgical Implants. NEJM
350: 1422-1429
[Full Text]
Siegenthaler, M. P., Brehm, K., Strecker, T., Hanke, T., Notzold, A., Olschewski, M., Weyand, M., Sievers, H., Beyersdorf, F.
(2004). The Impella Recover microaxial left ventricular assist device reduces mortality for postcardiotomy failure: a three-center experience. J. Thorac. Cardiovasc. Surg.
127: 812-822
[Abstract][Full Text]
Dixon, L. J., Murtagh, J. G., Richardson, S. G., Chew, E. W.
(2004). Reduction in hospitalization rates following cardiac resynchronisation therapy in cardiac failure: experience from a single centre. Europace
6: 586-589
[Abstract][Full Text]
Walsh, M. N., Tavel, M. E.
(2003). Evaluation and Management of a Patient With Congestive Heart Failure. Chest
124: 728-731
[Full Text]
Nabavi, D. G., Stockmann, J., Schmid, C., Schneider, M., Hammel, D., Scheld, H. H., Ringelstein, E. B.
(2003). Doppler microembolic load predicts risk of thromboembolic complications in Novacor patients. J. Thorac. Cardiovasc. Surg.
126: 160-167
[Abstract][Full Text]
Miller, L. W.
(2003). Patient selection for the use of ventricular assist devices as a bridge to transplantation. Ann. Thorac. Surg.
75: S66-71
[Abstract][Full Text]
Blaxall, B. C., Tschannen-Moran, B. M., Milano, C. A., Koch, W. J.
(2003). Differential gene expression and genomic patient stratification following left ventricular assist device support. J Am Coll Cardiol
41: 1096-1106
[Abstract][Full Text]
Khot, U. N., Mishra, M., Yamani, M. H., Smedira, N. G., Paganini, E., Yeager, M., Buda, T., McCarthy, P. M., Young, J. B., Starling, R. C.
(2003). Severe renal dysfunction complicating cardiogenic shock is not a contraindication to mechanical support as a bridge to cardiac transplantation. J Am Coll Cardiol
41: 381-385
[Abstract][Full Text]
Delgado, D. H., Rao, V., Ross, H. J., Verma, S., Smedira, N. G.
(2002). Mechanical Circulatory Assistance: State of Art. Circulation
106: 2046-2050
[Full Text]
Siegenthaler, M. P., Martin, J.u., van de Loo, A., Doenst, T., Bothe, W., Beyersdorf, F.
(2002). Implantation of the permanent jarvik-2000 left ventricular assist device: A single-center experience. J Am Coll Cardiol
39: 1764-1772
[Abstract][Full Text]
McCafferty, M., Sorbellini, D., Cianci, P.
(2002). Telemetry to Home: Successful Discharge of Patients With Ventricular Assist Devices. Crit Care Nurse
22: 43-51
[Full Text]
Snyder, T. A., Watach, M. J., Litwak, K. N., Wagner, W. R.
(2002). Platelet activation, aggregation, and life span in calves implanted with axial flow ventricular assist devices. Ann. Thorac. Surg.
73: 1933-1938
[Abstract][Full Text]
Bridges, C. R., Burkman, J. M., Malekan, R., Konig, S. M., Chen, H., Yarnall, C. B., Gardner, T. J., Stewart, A. S., Stecker, M. M., Patterson, T., Stedman, H. H.
(2002). Global cardiac-specific transgene expression using cardiopulmonary bypass with cardiac isolation. Ann. Thorac. Surg.
73: 1939-1946
[Abstract][Full Text]
Lim, M. E., Pope, J.
(2002). The Role of Echocardiography in the Evaluation of Patients With Left Ventricular Assist Devices: A Literature Review. Journal of Diagnostic Medical Sonography
18: 61-70
[Abstract]
POPPAS, A., ROUNDS, S.
(2002). Congestive Heart Failure. Am. J. Respir. Crit. Care Med.
165: 4-8
[Full Text]
Grabellus, F., Levkau, B., Sokoll, A., Welp, H., Schmid, C., Deng, M. C, Takeda, A., Breithardt, G., Baba, H. A
(2002). Reversible activation of nuclear factor-{kappa}B in human end-stage heart failure after left ventricular mechanical support. Cardiovasc Res
53: 124-130
[Abstract][Full Text]
Hunt, S. A., Baker, D. W., Chin, M. H., Cinquegrani, M. P., Feldmanmd, A. M., Francis, G. S., Ganiats, T. G., Goldstein, S., Gregoratos, G., Jessup, M. L., Noble, R. J., Packer, M., Silver, M. A., Stevenson, L. W., Gibbons, R. J., Antman, E. M., Alpert, J. S., Faxon, D. P., Fuster, V., Gregoratos, G., Jacobs, A. K., Hiratzka, L. F., Russell, R. O., Smith, S. C. Jr
(2001). ACC/AHA Guidelines for the Evaluation and Management of Chronic Heart Failure in the Adult: Executive Summary A Report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (Committee to Revise the 1995 Guidelines for the Evaluation and Management of Heart Failure). Circulation
104: 2996-3007
[Full Text]
Sodian, R., Loebe, M., Schmitt, C., Potapov, E. V., Siniawski, H., Muller, J., Hausmann, H., Zurbruegg, H. R., Weng, Y., Hetzer, R.
(2001). Decreased plasma concentration of brain natriuretic peptide as a potential indicator of cardiac recovery in patients supported by mechanical circulatory assist systems. J Am Coll Cardiol
38: 1942-1949
[Abstract][Full Text]
Hunt, S. A., Baker, D. W., Chin, M. H., Cinquegrani, M. P., Feldman, A. M., Francis, G. S., Ganiats, T. G., Goldstein, S., Gregoratos, G., Jessup, M. L., Noble, R. J., Packer, M., Silver, M. A., Stevenson, L. W., Gibbons, R. J., Antman, E. M., Alpert, J. S., Faxon, D. P., Fuster, V., Gregoratos, G., Jacobs, A. K., Hiratzka, L. F., Russell, R. O., Smith, S. C. Jr
(2001). ACC/AHA guidelines for the evaluation and management of chronic heart failure in the adult: executive summary: A report of the american college of cardiology/american heart association task force on practice guidelines (committee to revise the 1995 guidelines for the evaluation and management of heart failure) developed in collaboration with the international society for heart and lung transplantation endorsed by the heart failure society of america. J Am Coll Cardiol
38: 2101-2113
[Full Text]
Haft, J. W., Montoya, P., Alnajjar, O., Posner, S. R., Bull, J. L., Iannettoni, M. D., Bartlett, R. H., Hirschl, R. B.
(2001). An artificial lung reduces pulmonary impedance and improves right ventricular efficiency in pulmonary hypertension. J. Thorac. Cardiovasc. Surg.
122: 1094-1100
[Abstract][Full Text]
Thomas, C. E., Jichici, D., Petrucci, R., Urrutia, V. C., Schwartzman, R. J.
(2001). Neurologic complications of the Novacor left ventricular assist device. Ann. Thorac. Surg.
72: 1311-1315
[Abstract][Full Text]
Gordon, S. M., Schmitt, S. K., Jacobs, M., Smedira, N. M., Goormastic, M., Banbury, M. K., Yeager, M., Serkey, J., Hoercher, K., McCarthy, P. M.
(2001). Nosocomial bloodstream infections in patients with implantable left ventricular assist devices. Ann. Thorac. Surg.
72: 725-730
[Abstract][Full Text]
Barbone, A., Holmes, J. W., Heerdt, P. M., The', A. H.S., Naka, Y., Joshi, N., Daines, M., Marks, A. R., Oz, M. C., Burkhoff, D.
(2001). Comparison of Right and Left Ventricular Responses to Left Ventricular Assist Device Support in Patients With Severe Heart Failure: A Primary Role of Mechanical Unloading Underlying Reverse Remodeling. Circulation
104: 670-675
[Abstract][Full Text]
Cazeau, S., Leclercq, C., Lavergne, T., Walker, S., Varma, C., Linde, C., Garrigue, S., Kappenberger, L., Haywood, G. A., Santini, M., Bailleul, C., Daubert, J.-C., The Multisite Stimulation in Cardiomyopathies (MUS,
(2001). Effects of Multisite Biventricular Pacing in Patients with Heart Failure and Intraventricular Conduction Delay. NEJM
344: 873-880
[Abstract][Full Text]
Leprince, P., Rahmati, M., Bonnet, N., Bors, V., Rama, A., Leger, Ph., Gandjbakhch, I., Pavie, A.
(2001). Expanded polytetrafluoroethylene membranes to wrap surfaces of circulatory support devices in patients undergoing bridge to heart transplantation. Eur. J. Cardiothorac. Surg.
19: 302-306
[Abstract][Full Text]
Hetzer, R., Muller, J. H., Weng, Y.-g., Meyer, R., Dandel, M.
(2001). Bridging-to-recovery. Ann. Thorac. Surg.
71
: S109-S113
[Abstract][Full Text]
Smolens, I. A., Pagani, F. D., Bolling, S. F.
(2000). Mitral valve repair in heart failure. Eur J Heart Fail
2: 365-371
[Abstract][Full Text]
Rose, A. G., Park, S. J., Bank, A. J., Miller, L. W.
(2000). Partial aortic valve fusion induced by left ventricular assist device. Ann. Thorac. Surg.
70: 1270-1274
[Abstract][Full Text]
Deng, M. C, De Meester, J. M J, Smits, J. M A, Heinecke, J., Scheld, H. H, Treasure, T., Murday, A.
(2000). Effect of receiving a heart transplant: analysis of a national cohort entered on to a waiting list, stratified by heart failure severity Commentary: Time for a controlled trial?. BMJ
321: 540-545
[Abstract][Full Text]
Tjan, T. D.T., Asfour, B., Hammel, D., Schmidt, C., Scheld, H. H., Schmid, C.
(2000). Wound complications after left ventricular assist device implantation. Ann. Thorac. Surg.
70: 538-541
[Abstract][Full Text]
Marelli, D., Laks, H., Fazio, D., Hamilton, M. A., Fonarow, G. C., Meehan, D. A., Moriguchi, J. D.
(2000). Mechanical assist strategy using the BVS 5000i for patients with heart failure. Ann. Thorac. Surg.
70: 59-66
[Abstract][Full Text]
Loebe, M., Drews, T., Potapov, E., Ngo, D.-V., zu Dohna, R., Hetzer, R.
(2000). Device selection in mechanical circulatory support. Perfusion
15: 313-318
Gagnon, D., Petty, M., Lahpor, J. R
(2000). HeartMate(R) family of left ventricular assist systems. Perfusion
15: 345-354
Schmid, C., Wilhelm, M., Rothenburger, M., Nabavi, D., Deng, M. C., Hammel, D., Scheld, H. H.
(2000). Effect of high dose platelet inhibitor treatment on thromboembolism in Novacor patients. Eur. J. Cardiothorac. Surg.
17: 331-335
[Abstract][Full Text]
El-Banayosy, A., Arusoglu, L., Kizner, L., Tenderich, G., Minami, K., Inoue, K., Korfer, R.
(2000). NOVACOR LEFT VENTRICULAR ASSIST SYSTEM VERSUS HEARTMATE VENTED ELECTRIC LEFT VENTRICULAR ASSIST SYSTEM AS A LONG-TERM MECHANICAL CIRCULATORY SUPPORT DEVICE IN BRIDGING PATIENTS: A PROSPECTIVE STUDY. J. Thorac. Cardiovasc. Surg.
119: 581-587
[Abstract][Full Text]
Deng, M. C., Tjan, T. D.T., Asfour, B., Scheld, H. H.
(1999). Left ventricular assist devices -- reasons to be enthusiastic. Eur J Heart Fail
1: 289-291
[Full Text]
Rose, E. A., Gelijns, A. C., Moskowitz, A. J., Heitjan, D. F., Stevenson, L. W., Dembitsky, W., Long, J. W., Ascheim, D. D., Tierney, A. R., Levitan, R. G., Watson, J. T., Ronan, N. S., Shapiro, P. A., Lazar, R. M., Miller, L. W., Gupta, L., Frazier, O. H., Desvigne-Nickens, P., Oz, M. C., Poirier, V. L., Meier, P., the Randomized Evaluation of Mechanical Assistance,
(2001). Long-Term Use of a Left Ventricular Assist Device for End-Stage Heart Failure. NEJM
345: 1435-1443
[Abstract][Full Text]